Every dwelling unit in an apartment house must have a separate circuit for:
general lighting;
the dryer;
the electric range;
the furnace;
the hot water tank; and
Every efficiency dwelling unit must have a separate circuit for:
the kitchen area;
the living area; and
Every housekeeping room must have a separate circuit for:
general lighting; and
There shall be at least one supplied electric light fixture in every:
bathroom and water closet compartment;
furnace room;
common hallway; and
Duplex outlets are required as follows:
Dwelling unit:
Kitchen: two;
Living room: two;
Bathroom: one, which may be in a wall lighting fixture;
Other habitable room: two, on opposite walls.
Efficiency dwelling unit: four, two in kitchen area;
Date Passed: Monday, February 28, 2005
Effective Date: Saturday, April 2, 2005
ORD C33594 Section 6
www.spokanecity.org is the official website of the City of Spokane, 808 W. Spokane Falls Blvd., Spokane, WA 99201. Need further assistance? Please call the City help desk at (509) 755-CITY or visit the City feedback page. Use of this website constitutes your acceptance of the website disclaimer and terms of use. Your privacy is important to us, for more information see our privacy policy.